Lufft Ventus-UMB Ultrasonic Wind Sensor
Product Number: 8371.UMTWind Speed
Transducer Heater
Analog Output
Overview
VENTUS: Very robust, precise and maintenance-free measurement of wind speed, wind gust and wind direction even in the lowest temperature. The accurate wind sensor uses the run-time differential method for determining the wind speed and wind direction. It provides output for instantaneous values, vector and scalar means, the maximum gust of wind and wind direction, the maximum/minimum values and the virtual temperature. Data output through serial or analogue interfaces provides compatibility of the Lufft Ventus for commercially available hydrometeorological dataloggers and PLC systems. An automatic heater ensures reliable operation even in the lowest temperature.
Benefits
Vibration and seawater resistant, integrated heater guarantees ice-free operation in extremely low temperatures until -40 °C
Built-in data pre-processing, universal interfaces and selectable output protocols – compatible with OTT-dataloggers, commercially available HydroMet dataloggers and PLS systems.
Maintenance-free operation – no moving parts that can wear out thanks to ultrasonic measuring method; no need for re-calibration.
Specifications
Technical Attributes
| Accuracy | Wind Direction: ±2° RMSE |
| Ambient Temperature | -40 - +176 °F (-40 - +80 °C) |
| Analog Output | Yes |
| Analogue Ouput Signal | 4 - 20 mA or 0 - 10 V or 2 - 2000 Hz |
| Analogue Outputs | 4 - 20 mA or 0 - 10 V |
| Baud rate | 1200 - 57600 |
| Bus Operation | Up to 32 devices |
| Cable Connection | 8 pole plug |
| Casing IP Rating | IP68 |
| Diameter, Outer | Ø50 mm (2 in) |
| Dimensions (free text) | Ø approx. 5.9 in (150 mm), H approx. 6.7 in (170 mm) |
| Factory Certificate | Yes |
| Housing material | Aluminium, seawater - proof |
| Interface | RS485 semi-/full duplex, isolated |
| Measurement Range EU | Wind Direction: 0 - 359.9 ° Wind Speed: 0 - 295.3 ft/s (0 - 90 m/s) Virtual Temperature: -58 - +158 °F (-50 - +70 °C) Air Pressure: 300 - 1200 hPa |
| Measurement technology | Ultrasonic |
| Operating Height | 3827 yd (Max) (3500 m) |
| Operating voltage | 12 - 24 VDC / 1.2 VA (without heating) 24 VDC / 240 VA (140 VA + 100 VA) (with heating) |
| Product highlights | Ice-free operation in extreme freezing conditions due to additional transducer heater Maintenance-free measurement Suitable for extreme ambient conditions Vibration and seawater resistant Compatible interfaces |
| Resolution EU | Data output: 16 bit Wind Direction: 0.1 ° Wind Speed: 0.33 ft/s Virtual Temperature: 0.2 °F Air Pressure: 0.1 hPa |
| Sample rate | Instantaneous: 1 - 10 s Average: 1 - 10 min |
| System Monitoring & Controls: Local Status Indication | Heating, sensor failure |
| Testing | Jarring Test: According to IEC 60945 Corrosion Test: According to MIL-STD-810 Method 509.3 Ice-free Test: According to MIL-STD-810F Method 521.2 Highly Accelerated Life Test |
| Transducer Heater | No |
| Weight EU | Approx. 3.6 lbs (1.6 kg) |
| Wind Speed | 0 - 295 ft/s (0 - 90 m/s) |