Skip to content
  • Current region: English
  • Select a different region:
  • English
  • There are no suggestions because the search field is empty.
Close
  • Products
  • Services
  • Applications
  • Resources
  • Company
  • Support
Lufft Active Road Sensor ARS31Pro-UMB, External Temperature Sensor, 164 ft Supply Cable
Lufft Active Road Sensor ARS31Pro-UMB, External Temperature Sensor, 164 ft Supply Cable
csm_8810_U05X_ARS31_ARS31Pro_Abmessung_06_fece12f67b
csm_8810_U051_DE_Installation_RWIS-station_WS600-ARS31Pro-IRS31Pro_3_06_7506b5afd1
8810_U051_IT_Airport_Malpensa_Milano_IRS31PRO-ARS31_combination

Lufft Active Road Sensor ARS31Pro-UMB, External Temperature Sensor, 164 ft Supply Cable

Product Number: 8810.U051

Overview

The active road surface UMB sensor ARS31Pro is flush-mounted in the road or runway surface and measures the freezing temperature by means of active cooling and heating of the sensor surface. Through this, it's independent from the de-icing material. In addition, it measures the road surface temperature. This surface temperature sensor is integrated into a second housing which is connected to the ARS31Pro-UMB. The distance between the two housings is 50 cm. One additional measurement is carried out to find out critical conditions in the next few hours. This early alert message delivers extra road surface condition information in addition to the real time road conditions. The two-section housing design allows the combined electronics unit to be removed for maintenance purposes at any time, in just a few minutes. In conjunction with the interface converter 8160.UISO, the sensor can be built into new and existing UMB networks. The sensors are addressable and can be networked.

Benefits

Freezing point is determined independently from the de-icing material

Active cooling concept enables the freezing point determination independently from de-icing material.

Maintenance, calibration and replaceability

Sensor consists of two parts: replaceable sensor head with electronics and fixed mounted socket.

Extra road surface temperature sensor

Actual surface temperature sensor is integrated into a second housing for accurate measurements not influenced by the active colling/heating element. One additional measurement is carried out to find out critical conditions in the next few hours.

Invasive technology allows

Permanent usage on runways where non-invasive sensors cannot be used.

Specifications

-
Technical Attributes
Accuracy External road surface temperature: ±0.4 °F (-14 - +50 °F), or ±1 °F
Cable Connection Open wires 0.5 mm²
Cable Length 164 ft (50 m)
Casing IP Rating IP68
Communication RS 485-UMB
Connector (text) CAGE CLAMP, WAGO, (cross-section 0,5 mm²)
Cooling Sensor Active
Digital outputs UMB
Dimensions (free text) Ø 4.72441 in, H 1.97 in (Ø 120 mm, H 50 mm)
Height above Absolute Altitude 9843 ft (3000 m)
Interface RS485 Baud rate: 1200 - 38400 bit/s (Standard: 19200)
Material enclosures Salt , UV resistant modified PTFE
Measurement distance in-situ
Measurement Range EU Road surface temperature: -40 - +176 °F Freezing point: -40 - +32 °F Water film height: 0 - 0.16 in Friction (Grip) [slippery-dry]: 0 - 1 Ice Percentage: 0 - 100 %
Measurement technology Peltier element: Active cooling and heating Road surface temperature: NTC
Number of Depth Sensors 0
Number of Depth Temperature Sensors 0
Number of Related Temperature Sensors 1
Operating humidity 0 - 100 % RH
Operating temp range 1 -40 - +176 °F
Parameters Measured Road surface temperature Freezing point
Power supply 24 VDC ±10 %
Product highlights Two part housing design allows easy maintenance/re-calibration Llow energy consumption allows solar operation Freezing point determined independently from de-icing material
Resolution EU External road surface temperature - 0.1
Standard storage temperature -40 - +158 °F (in packaging)
Weight EU Approx. 2.4 lb (1100 g)