Skip to content
  • Current region: English
  • Select a different region:
  • English
  • There are no suggestions because the search field is empty.
Close
  • Products
  • Services
  • Applications
  • Resources
  • Company
  • Support
SUTRON Stage Discharge Recorder, with Analog input and 4-20mA outputs and SD Card Slot,with Shaft Encoder
SUTRON Stage Discharge Recorder, with Analog input and 4-20mA outputs and SD Card Slot,with Shaft Encoder
SDR-2
SDR-N2
SDR-N3
SDR-3
SDR-9

SUTRON Stage Discharge Recorder, with Analog input and 4-20mA outputs and SD Card Slot,with Shaft Encoder

Product Number: SDR-0001-4SD
Shaft Encoder
SD Card
Analogue inputs
This product has been discontinued. Please connect with your sales representative for assistance.

Overview

SDR is a Logging Shaft Encoder used in surface water & groundwater applications. Front panel programmable, it holds over one year of data, & operates for over one year on alkaline batteries. SDR supports dual sensors to measure a second stage using an analog or SDI-12 sensor. It supports rating tables and incorporates standard flume and weir equations.

Benefits

Dual sensor

Setup SDR to measure a second stage using an analog* or SDI-12 sensor.

Rating table

Compute discharge using a rating table with up to 50 points.

Averaging

Stage can be computed by averaging multiple samples over a user-set period.

Specifications

-
Technical Attributes
Analog Output Yes
Analogue inputs Yes
Analogue Ouput Signal 4 - 20 mA
Analogue Outputs Stage / Water Level or Discharge
Calculations Discharge using Parshall Flume, Broad Crested Weir equations, Dual Sensor, Rating Table or general purpose equation with user entered constants. Calculation of daily volume and daily average stage.
Control and Display Display Type: 2 x 20 LCD with backlight Keypad Type: 6 button
Data storage ˃ 300,000 readings
Dimensions (free text) 4.5 x 4 x 7 in (11.5 x 10.2 x 17.8 cm)
Interface SDI-12, RS-232
Material enclosures NEMA 3, IP63 resists dripping water & spray
Measuring interval 15-minute (default) 1, 5, and 10-min user selectable
Mounting configurations Supported Wheels: 1 ft, 0.375, 0.5 m, and custom
Operating temp range 1 -40 - +140 °F (-40 - +60 °C)
Parameters Measured Stage / Water Level, Internal Temperature, Battery
Power Consumption ˂3.5 mA @12 VDC
Power supply 5.5 - 16 VDC
Programming Via front panel or SDR communicator program
Protocol MODBUS Slave. SCP, SDI-12
Resolution Analog input measures 0 - 5 V sensor, 4 - 20 mA sensor or resistive bridge sensor
SD Card Yes
Shaft Encoder Yes
Shaft Length 5/16" Diameter